Select Page

NAS6703 Thru NAS6710

NAS Bolts – NAS6703 Thru NAS6710

Bolt, Hex Head, Close Tolerance, A-286 CRES, Long Threads, Self-Locking & Non-Locking

Jet-Tek is a manufacturer and distributor of NAS Bolts. Blanks in all diameters available which can be completed in 2-3
weeks based on your requirement. Parts include Manufacturer and material certifications with chemical and physical test
reports at no charge. Contact us at (800) 804-7876 for a free quote, or pleasesubmit a RFQ here.

Figure I – Bolt Configuration

Table I – NAS Bolt Dimensions

Basic Number Thread UNJF-3A A B MIN ØC MIN /3/ ØD F /10/ H +.015 -.000 J /11/ ØK ±.01
Unplated Plated or Coated
MAX MIN MAX MIN MAX MIN
NAS6703 .1900-32 .376 .367 .410 .335 .1895 .1890 .1895 .1885 .156 .110 .094 .19
NAS6704 .2500-28 .439 .429 .480 .398 .2495 .2490 .2495 .2485 .178 .125 .107 .25
NAS6705 .3125-24 .502 .492 .552 .460 .3120 .3115 .3120 .3110 .208 .156 .125 .31
NAS6706 .3750-24 .564 .554 .623 .523 .3745 .3740 .3745 .3735 .208 .188 .125 .38
NAS6707 .4375-20 .690 .678 .764 .648 .4370 .4365 .4370 .4360 .250 .219 .150 .44
NAS6708 .5000-20 .752 .741 .836 .710 .4995 .4990 .4995 .4985 .250 .250 .150 .50
NAS6709 .5625-18 .877 .865 .978 .835 .5615 .5610 .5615 .5605 .278 .281 .167 .56
NAS6710 .6250-18 .940 .928 1.050 .898 .6240 .6235 .6240 .6230 .278 .312 .167 .62
Basic Number M ±.010 ØN ±.010 -.000 ØP ±.010 -.000 /4/ R RAD S +.015 -.000 (T) /5/ U MAX ØTD Inspection Data
X /6/ Y /6/ Z /7/
MAX MIN MAX MIN
NAS6703 .164 .046 .070 .020 .010 .073 .345 .039 .184 .181 .005 .0045 .0040
NAS6704 .178 .046 .076 .020 .010 .083 .425 .045 .244 .241 .006 .0045 .0030
NAS6705 .181 .070 .076 .020 .010 .104 .469 .052 .306 .302 .008 .0045 .0030
NAS6706 .197 .070 .106 .025 .015 .125 .578 .052 .368 .364 .009 .0045 .0025
NAS6707 .201 .070 .106 .025 .015 .146 .694 .062 .431 .426 .010 .006 .0025
NAS6708 .216 .070 .106 .030 .020 .167 .735 .062 .493 .488 .011 .006 .0020
NAS6709 .218 .070 .141 .035 .020 .188 .840 .068 .555 .550 .012 .006 .0020
NAS6710 .249 .070 .141 .040 .025 .208 .902 .068 .618 .612 .015 .006 .0020

Material:Cres – A286 (UNS S66286) conforming to the chemistry of AMS5731, AMS5732,
AMSS737 or AMS5853.
Locking element – nylon or equivalent per MIL-DTL-18240 and QPL-18240.

Heat Treat:Develop basic material properties as follows, with controls
perAMS-H-687-5-QR orAMS2759: 160 – 190 KSI FtU /19/

Finish:Unplated bolts – passivated per AMS2700, method 1, type 2 or type 8, class 4.
Passivated per AMS2700 method 1, type 8, class 4 – without post treatment or passivated per AMS2700 method 2- without
post treatment.
Cadmium plated bolts – cadmium plate per AMS-QQ-P-416, type II, class 2, identify with green dye or paint on the thread
end, maximum coverage may include the chamfer plus one incomplete thread.
Chromium plated –

    • Code C- Chromium plate per AMS-QQ-C-320, class 2 on shank only, all other surfaces cadmium plated, no chromium
      within .020 of line of tangency of head-to-shank fillet, chromium in thread runout permitted, chromium plated
      bolts not available with grip dash numbers 1 or 2.
    • Code E – Chromium plate per AMS-QQ-C-320, class 2a, plating on shank only, no plating on: top or sides of
      head, bearing surface of head, head-to- shank fillet, adjacent to fillet (within .020 minimum to .080 maximum of
      line of tangency between shank and radius r), and threads except runout.

May be plated, all surfaces not chromium plated shall be cadmium plated per AMS-QQ-P-416, type II, class 2, bolts shall
be shot peened per AMS2430 and the following requirements: cast steel shot of size 170 to 390, intensity .014A to .018A,
shot peen prior to chromium plating, thread rolling and cold working “R” radius, but after heat treating and grinding,
minimum areas to be shot peened: bearing surface of head, head-to-shank fillet, shank, and thread runout. Chromium
plated bolts not available with grip dash numbers 1 or 2.

  • Code G – all requirements identical to Code E except delete requirement for cadmium plating of non-chrome plated
    surfaces and add the following requirement: passivate entire bolt per AMS2700, method 1, type 2 or type 8, class 4
    after chromium plating.

Aluminum coated – aluminum coat per NAS4006.

Code:No finish code after basic number for cadmium plated bolts.
Add “A” after basic number for aluminum coated bolt, may be used with “D”, “H”, “L”, or “P” code.
Add “B” after basic number for bolts, passivated in accordance with AMS2700 method 2 – without post treatment, may be
used with “D”, “H”, “L”, or “P” code.
Add “C” after basic number for chromium plated bolts not requiring shot peening. Surfaces not chrome plated are cadmium
plated, do not use with “A”, “E”, “U”, or “G” codes.
Add “D” after basic number for drilled shank bolts. Do not use with “L” or “P” code. /18/
Add “E” after basic number for chromium plated bolts with mandatory shot peening. Surfaces not chromium plated are
cadmium plated, do not use with “A”, “C”, “U”, or “G” codes.
Add “G” after basic number for chromium plated bolts with mandatory shot peening. Surfaces not chromium plated are
passivated per AMS2700, method 1, type 2 or type 8, class 4 only, do not use with “A”, “C”, “U”, or “E” codes.
Add “H” after basic number for bolt with drilled head.
Add “L” after basic number for self-locking bolt with locking element type optional; See procurement spec below, do not
use “L” with “D” or “P” code.
Add “M” after basic number for bolts, passivated in accordance with AMS2700 method 1, type 8, class 4 – without post
treatment, may be used with “D”, “H”, “L”, or “P” code.
Add “P” after basic number for self-locking bolt with patch type locking element only; see procurement spec below, do
not use “P” with “D” or “L” code.
Add “U” after basic number for bolts, passivated per AMS2700, method 1, type 2 or type 8, class 4, may be used with “D”,
“H”, “L”, or “P” code.
Grip dash number indicates grip in .0625 increments (converted to three decimal places per ANSI Y14.5-1982). See table
II for tabulations of grip and length dimensions. /17/
Code letter “X” and “Y” following the grip dash number indicates replacement oversize repair bolt, (see last sheet).
If more than one code letter is used in sequence, arrange the letters alphabetically.

Example of Part Number: (See Oversize Bolts)

  • NAS6704-10 = BOLT, .2500-28 THREAD, .625 GRIP, UNDRILLED, NONLOCKING, CADMIUM PLATED.
  • NAS6704A10 = BOLT, .2500-28 THREAD, .625 GRIP, UNDRILLED, NONLOCKING, ALUMINUM COATED.
  • NAS6704B10 = BOLT, .2500-28 THREAD, .625 GRIP, UNDRILLED, NONLOCKING, PASSIVATED PER AMS2700, METHOD 2 – WITHOUT
    POST TREATMENT.
  • NAS6704D10 = BOLT, .2500-28 THREAD, .625 GRIP, DRILLED SHANK, UNDRILLED HEAD, NONLOCKING, CADMIUM PLATED.
  • NAS6704H10 = BOLT, .2500-28 THREAD, .625 GRIP, DRILLED HEAD, UNDRILLED SHANK, NONLOCKING, CADMIUM PLATED.
  • NAS6704DH10 = BOLT, .2500-28 THREAD, .625 GRIP, DRILLED SHANK, DRILLED HEAD, NONLOCKING, CADMIUM PLATED.
  • NAS6704L10 = BOLT, .2500-28 THREAD, .625 GRIP, UNDRILLED, SELF-LOCKING (LOCKING TYPE OPTIONAL; SEE PROCUREMENT
    SPEC BELOW), CADMIUM PLATED.
  • NAS6704P10 = BOLT, .2500-28 THREAD, .625 GRIP, UNDRILLED, SELF-LOCKING (PATCH TYPE; SEE PROCUREMENT SPEC BELOW),
    CADMIUM PLATED.
  • NAS6704PU10 = BOLT, .2500-28 THREAD, .625 GRIP, UNDRILLED, SELF-LOCKING (PATCH TYPE; SEE PROCUREMENT SPEC BELOW),
    PASSIVATED PER AMS2700, METHOD 1, TYPE 2 OR TYPE 8, CLASS 4.
  • NAS6704C10 = BOLT, .2500-28 THREAD, .625 GRIP, UNDRILLED, CHROMIUM PLATED WITHOUT MANDATORY SHOT PEENING, SURFACES
    NOT CHROMIUM PLATED ARE CADMIUM PLATED.
  • NAS6704E10 = BOLT, .2500-28 THREAD, .625 GRIP, UNDRILLED, CHROMIUM PLATED, WITH MANDATORY SHOT PEENING, SURFACES
    NOT CHROMIUM PLATED ARE CADMIUM PLATED.
  • NAS6704G10 = BOLT, .2500-28 THREAD, .625 GRIP, UNDRILLED, CHROMIUM PLATED, WITH MANDATORY SHOT PEENING, SURFACES
    NOT CHROMIUM PLATED ARE PASSIVATED PER AMS2700, METHOD 1, TYPE 2 OR TYPE 8, CLASS 4.
  • NAS6704MP10 = BOLT, .2500-28 THREAD, .625 GRIP, UNDRILLED, SELF-LOCKING (PATCH TYPE), PASSIVATED PER AMS2700,
    METHOD 1, TYPE 8, CLASS 4 – WITHOUT POST TREATMENT.

/ Notes: /

  1. GRIP LENGTH: FROM UNDER SIDE OF HEAD TO END OF FULL CYLINDRICAL PORTION OF SHANK.
  2. BEARING SURFACE SQUARENESS: WITHIN .003 FIM OF “ØD”.
  3. “ØC” MAX NOT TO EXCEED ACTUAL WIDTH ACROSS FLATS; MIN AS TABULATED IN TABLE I.
  4. “ØP” HOLE CENTERLINE WITHIN .010 AND NORMAL WITHIN 2° OF BOLT CENTERLINE.
  5. REFERENCE DIMENSIONS ARE FOR DESIGN PURPOSES ONLY AND ARE NOT AN INSPECTION REQUIREMENT.
  6. CONCENTRICITY: “ØC” AND “ØD” WITHIN “X” VALUES FIM, “ØD” AND MAJOR THREAD DIA WITHIN Y VALUES FIM.
  7. SHANK STRAIGHTNESS: WITHIN “Z” VALUES FIM PER INCH OF LENGTH.
  8. TOP OF HEAD SHALL BE FLAT ON THE 1.1250-12 AND 1.2500-12 SIZE BOLTS.
  9. PROTRUSION OF LOCKING ELEMENT SHALL BE CONTROLLED SO THAT IT WILL PASS FREELY, OR WITH FINGER PRESSURE, THROUGH A
    RING GAGE WITH DIAMETER OF .010 (+.001, -.000) GREATER THAN MAXIMUM MAJOR DIAMETER OF BOLT THREAD,
  10. “F” MIN (5 THREAD PITCHES) = REGION OF MINIMUM ENGAGEMENT WITH FEMALE THREAD REQUIRED TO MEET MIL-DTL-18240
    REQUIREMENTS, LOCKING ELEMENT WITHIN “F” REGION MUST DEVELOP REQUIRED TORQUE WHEN TESTED PER MIL-DTL-18240.
  11. FOR EASE IN STARTING, LOCKING ELEMENT SHALL NOT BE EFFECTIVE IN “J” AREA (3 THREAD PITCHES).
  12. MAGNETIC PERMEABILITY SHALL BE LESS THAN 2.0 (AIR = 1.0) FOR A FIELD STRENGTH H = 200 OERSTEDS USING A MAGNETIC
    PERMEABILITY INDICATOR PER ASTM A 342/A 342M, TEST METHOD 3.
  13. FOR CHROMIUM PLATED PARTS, THE CYLINDER DESCRIBED BY THE THREAD MAJOR DIAMETER (DIMENSION “ØTD”) MUST FALL WITHIN
    THE CYLINDER DESCRIBED BY THE SHANK DIAMETER (DIMENSION “ØD, PLATED OR COATED”).
  14. LOCKWIRE HOLES SHALL BE DRILLED WITHIN .010 OF CENTER OF HEX FLAT WHEN SPECIFIED BY PART NUMBER.
  15. HEAD MARKING: BASIC NUMBER PLUS GRIP DASH NUMBER PLUS “D”, “L”, OR “P”, WHEN APPLICABLE, PLUS MANUFACTURER’S
    SYMBOL, RAISED OR DEPRESSED ,010 MAX, ARRANGEMENT OPTIONAL.
    “D” IDENTIFIES BOLT WITH DRILLED SHANK,
    “L” IDENTIFIES BOLT WITH LOCKING ELEMENT (OPTIONAL TYPE),
    “P” IDENTIFIES BOLT WITH PATCH TYPE LOCKING ELEMENT ONLY,
    “A” ALUMINUM COATED, “C” CHROME PLATED AND “U”, “B” AND “M” PASSIVATED PER AMS2700 CODES NEED NOT APPEAR ON BOLT
    HEAD.
  16. SURFACE TEXTURE: “ØD”, HEAD-TO-SHANK FILLET, BEARING SURFACE OF HEAD, THREAD FLANKS AND THREAD ROOT: 32
    MICROINCHES Ra; ALL OTHER SURFACES; 125 MICROINCHES Ra PER ASME B46.1.
  17. INTERMEDIATE OR LONGER LENGTHS MAY BE SPECIFIED BY THE USE OF WHOLE GRIP DASH NUMBERS ONLY. NOMINAL LENGTH EQUALS
    NOMINAL GRIP PLUS “T”.
  18. IF REQUIRED, TENSILE TESTING OF BOLTS REQUIRING CROSS-DRILLED THREADS SHALL BE PERFORMED PRIOR TO DRILLING AND THE
    APPLICATION OF PLATING AND/OR COATINGS, WHEN BOLTS HAVE BEEN DRILLED, STRENGTH MAY BE VERIFIED BY SHEAR TESTING, IN
    LIEU OF TENSILE TESTING, IN ACCORDANCE WITH NASM1312, USERS SHOULD BE AWARE THAT FASTENERS WITH CROSS-DRILLED
    THREADS MAY EXHIBIT A REDUCTION IN TENSILE STRENGTH.
  19. THE EFFECT OF COLD WORK AND AGING INDUCED DURING THE MANUFACTURING CYCLE MAY INCREASE THE ULTIMATE TENSILE
    STRENGTH OF THE FINISHED PART, BUT ANY PART (TYPE I, II OR III AS LISTED IN NAS4003) SHALL NOT EXCEED 1.3 TIMES THE
    SPECIFIED TYPE I MINIMUM TENSILE VALUES AS LISTED IN NAS4003 TABLE III.
  20. DIMENSIONS TO BE MET AFTER PLATING.
  21. DIMENSIONS IN INCHES.
  22. REMOVE ALL BURRS AND SHARP EDGES.
  23. THIS STANDARD TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
  24. REFERENCED DOCUMENTS SHALL BE THE ISSUE IN EFFECT ON DATE OF INVITATIONS FOR BID.
  25. UNLESS OTHERWISE SPECIFIED, PART INVENTORY MANUFACTURED TO PREVIOUS REVISIONS OF THE APPLICABLE DRAWING OR
    SPECIFICATION MAY BE PROCURED AND USED UNTIL STOCK IS DEPLETED.

Procurement Specification:NAS4003, EXCEPT AS NOTED, COLD WORK OF HEAD TO SHANK FILLET
RADIUS AND FATIGUE TESTING ARE NOT REQUIRED FOR NAS6703 BOLTS, LOCKING ELEMENT FOR SELF-LOCKING BOLTS: PER NASM15981 AND
MIL-DTL-18240, LOCKING ELEMENT TYPE, INCLUDING PATCH TYPE, IS OPTIONAL WHEN “L” CODE IS SPECIFIED, PATCH TYPE LOCKING
ELEMENT (WITH NO METAL REMOVED) IS REQUIRED WHEN “P” CODE IS SPECIFIED, LOCKING ELEMENT MUST BE SUPPLIED BY A QUALIFIED
SOURCE LISTED IN QPL-18240 OR APPROVED FOR LISTING IN QPL-18240, SHIPPING NOTICE SHOULD IDENTIFY SUPPLIER OF BOLT AND
LOCKING ELEMENT SEPARATELY.

Table II – NAS Bolt Grip and Length Dimensions

Grip Dash No. Grip ±.010 Length ±.015 *17
Basic Number and Thread Size
NAS6703
.1900-32
NAS6704
.2500-28
NAS6705
.3125-24
NAS6706
.3750-24
NAS6707
.4375-20
NAS6708
.5000-20
NAS6709
.5625-18
NAS6710
.6250-18
1 .062 .407 .487 .531 .640 .756 .797 .902 .964
2 .125 .470 .550 .594 .703 .819 .860 .965 1.027
3 .188 .533 .613 .657 .766 .882 .923 1.028 1.090
4 .250 .595 .675 .719 .828 .944 .985 1.090 1.152
5 .312 .657 .737 .781 .890 1.006 1.047 1.152 1.214
6 .375 .720 .800 .844 .953 1.069 1.110 1.215 1.277
7 .438 .783 .863 .907 1.016 1.132 1.173 1.278 1.340
8 .500 .845 .925 .969 1.078 1.194 1.235 1.340 1.402
9 .562 .907 .987 1.031 1.140 1.256 1.297 1.402 1.464
10 .625 .970 1.050 1.094 1.203 1.319 1.360 1.465 1.527
11 .688 1.033 1.113 1.157 1.266 1.382 1.423 1.528 1.590
12 .750 1.095 1.175 1.219 1.328 1.444 1.485 1.590 1.652
13 .812 1.157 1.237 1.281 1.390 1.506 1.547 1.652 1.714
14 .875 1.220 1.300 1.344 1.453 1.569 1.610 1.715 1.777
15 .938 1.283 1.363 1.407 1.516 1.632 1.673 1.778 1.840
16 1.000 1.345 1.425 1.469 1.578 1.694 1.735 1.840 1.902
17 1.062 1.407 1.487 1.531 1.640 1.756 1.797 1.902 1.964
18 1.125 1.470 1.550 1.594 1.703 1.819 1.860 1.965 2.027
19 1.188 1.533 1.613 1.657 1.766 1.882 1.923 2.028 2.090
20 1.250 1.595 1.675 1.719 1.828 1.944 1.985 2.090 2.152
21 1.312 1.657 1.737 1.781 1.890 2.006 2.047 2.152 2.214
22 1.375 1.720 1.800 1.844 1.953 2.069 2.110 2.215 2.277
23 1.438 1.783 1.863 1.907 2.016 2.132 2.173 2.278 2.340
24 1.500 1.845 1.925 1.969 2.078 2.194 2.235 2.340 2.402
25 1.562 1.907 1.987 2.031 2.140 2.256 2.297 2.402 2.464
26 1.625 1.970 2.050 2.094 2.203 2.319 2.360 2.465 2.527
27 1.688 2.033 2.113 2.157 2.266 2.382 2.423 2.528 2.590
28 1.750 2.095 2.175 2.219 2.328 2.444 2.485 2.590 2.652
29 1.812 2.157 2.237 2.281 2.390 2.506 2.547 2.652 2.714
30 1.875 2.220 2.300 2.344 2.453 2.569 2.610 2.715 2.777
31 1.938 2.283 2.363 2.407 2.516 2.632 2.673 2.778 2.840
32 2.000 2.345 2.425 2.469 2.578 2.694 2.735 2.840 2.902
34 2.125 2.470 2.550 2.594 2.703 2.819 2.860 2.965 3.027
36 2.250 2.595 2.675 2.719 2.828 2.944 2.985 3.090 3.152
38 2.375 2.720 2.800 2.844 2.953 3.069 3.110 3.215 3.277
40 2.500 2.845 2.925 2.969 3.078 3.194 3.235 3.340 3.402
42 2.625 2.970 3.050 3.094 3.203 3.319 3.360 3.465 3.527
44 2.750 3.095 3.175 3.219 3.328 3.444 3.485 3.590 3.652
46 2.875 3.220 3.300 3.344 3.453 3.569 3.610 3.715 3.777
48 3.000 3.345 3.425 3.469 3.578 3.694 3.735 3.840 3.902
50 3.125 3.470 3.550 3.594 3.703 3.819 3.860 3.965 4.027
52 3.250 3.595 3.675 3.719 3.828 3.944 3.985 4.090 4.152
54 3.375 3.720 3.800 3.844 3.953 4.069 4.110 4.215 4.277
56 3.500 3.845 3.925 3.969 4.078 4.194 4.235 4.340 4.402
58 3.625 3.970 4.050 4.094 4.203 4.319 4.360 4.465 4.527
60 3.750 4.095 4.175 4.219 4.328 4.444 4.485 4.590 4.652
62 3.875 4.220 4.300 4.344 4.453 4.569 4.610 4.715 4.777
64 4.000 4.345 4.425 4.469 4.578 4.694 4.735 4.840 4.902

For NAS Bolts Repair Work Only

.0156 and .0312 Oversize Shank for Replacement of Bolts Shown at Top

Figure 2 – Oversize NAS Bolts Configuration
(See Above for Material, Finish, Procurement Information and Dimensions Not Shown)

Table III – Oversize NAS Part Numbers and Dimensions

Part Number Examples (For Cadmium Plated, Nonlocking, Undrilled Shank) Nominal Thread Size ØD, .0156 Oversize Shank
Drilled Head Undrilled Head Unplated Bolts Plated or Coated Bolts
MAX MIN MAX MIN
NAS6703H-*X NAS6703-*X .1900-32 .2026 .2021 .2026 .2016
NAS6704H-*X NAS6704-*X .2500-28 .2651 .2646 .2651 .2641
NAS6705H-*X NAS6705-*X .3125-24 .3276 .3271 .3276 .3266
NAS6706H-*X NAS6706-*X .3750-24 .3901 .3896 .3901 .3891
NAS6707H-*X NAS6707-*X .4375-20 .4526 .4521 .4526 .4516
NAS6708H-*X NAS6708-*X .5000-20 .5151 .5146 .5151 .5141
NAS6709H-*X NAS6709-*X .5625-18 .5771 .5766 .5771 .5761
NAS6710H-*X NAS6710-*X .6250-18 .6396 .6391 .6396 .6386
ØD, .0312 Oversize Shank
NAS6703H-*Y NAS6703-*Y .1900-32 .2182 .2177 .2182 .2172
NAS6704H-*Y NAS6704-*Y .2500-28 .2807 .2802 .2807 .2797
NAS6705H-*Y NAS6705-*Y .3125-24 .3432 .3427 .3432 .3422
NAS6706H-*Y NAS6706-*Y .3750-24 .4057 .4052 .4057 .4047
NAS6707H-*Y NAS6707-*Y .4375-20 .4682 .4677 .4682 .4672
NAS6708H-*Y NAS6708-*Y .5000-20 .5307 .5302 .5307 .5297
NAS6709H-*Y NAS6709-*Y .5625-18 .5927 .5922 .5927 .5917
NAS6710H-*Y NAS6710-*Y .6250-18 .6552 .6547 .6552 .6542

* = Grip Dash Number in .0625 Increments.

 

REQUEST A QUOTE